Automate edge fiber changes in under a minute—without sending people to the site.
Micro sites, MEC rooms, private 5G huts—edge infrastructure means lots of change requests hitting locations with no on-site expertise. A carrier hotel might see dozens of cross-connect orders per week. A distributed MEC deployment might span fifty locations across a metro area, each with a single cabinet and zero dedicated staff.
Manual patching at scale creates three compounding problems:
Delays: Every change requires dispatch scheduling, travel time, and site access coordination. A "15-minute patch" becomes a 3-day ticket when the next available window is Thursday.
Error risk: Wrong port, wrong customer path, reversed polarity. Mistakes happen more often under time pressure, and edge sites rarely have senior technicians available to double-check work.
Weak auditability: Handwritten notes, photos texted to a supervisor, spreadsheet updates days later. When a customer disputes a change or an outage needs root-cause analysis, the trail goes cold.
As edge deployments scale, cable growth becomes exponential. Back-to-back rack scaling turns structured cabling into spaghetti—and every new service requires another truck roll.

Zero-touch at Layer 0 means fiber changes execute remotely via workflow or API—not hands in a cabinet.
The operational model:
Humans go on-site for planned hardware installs, break/fix replacements, and periodic maintenance. They don't travel for routine moves, adds, and changes.
"Zero-touch is not 'no humans ever.' It's 'no routine hands-on patching.'"
This distinction matters for edge economics. You're not eliminating field technicians—you're redeploying them from repetitive patching to higher-value work while cutting dispatch volume by 60–80% on mature deployments.
Mobile edge compute nodes need fast turn-up for new services and rapid path changes when capacity shifts. A content provider spinning up a new cache node shouldn't wait three days for a cross-connect. With automated switching, provisioning completes in the same session as the service order.
Fronthaul and backhaul fibers require periodic rerouting during maintenance windows, RAN upgrades, or capacity rebalancing. Manual patching during a maintenance window introduces risk—wrong fiber, extended outage, missed cutover time. Automated switching executes the change in under a minute with rollback capability if the new path doesn't come up clean.
Colo pods, modular data centers, and enterprise edge rooms see constant moves/adds/changes as tenants shift workloads. Opening the cabinet for every change means key management overhead, contamination risk in sealed environments, and scheduling conflicts when multiple customers need changes the same week.
Traditional structured cabling hits a wall when every new customer means new patch cords, new trunk capacity, and new cable management headaches. Automated cross-connects let you keep adding ports without rebuilding the cabling model—reuse trunks and let the switch handle the logical layer.
Proof point: Switching completes in 36–60 seconds, and changes can be queued and batched for coordinated cutover windows.
The architecture separates one-time physical install from ongoing logical changes:
Patch once at install: Structured trunks connect edge devices to the switch's port field. This cabling is permanent and labeled—it doesn't change when services change.
Software-controlled cross-connects: When a provisioning system requests a new path, the switch's robotic mechanism physically mates the fibers. The connection is real (not multiplexed, not wavelength-routed)—just automated patching.
Passive latching continuity: Once a connection is made, it holds mechanically. Power loss, brownouts, or maintenance reboots don't drop established paths. This is critical for edge sites running on battery backup or generator failover.
The result: edge sites operate like a programmable patch panel. The physical layer becomes as controllable as the logical layer above it.

Edge deployments demand carrier-class optical performance—especially when services traverse multiple hops before reaching core infrastructure.
| Parameter | Specification | Notes |
|---|---|---|
| Provisioning time | Hours to days; technician scheduling | Minutes; queued tasks execute within change windows |
| Risk of mispatch | Medium to high in busy rooms | Very low; port mapping, software validation, atomic execution |
| Port density | Limited by panels and craft access | Thousands of LC/UPC ports per standard 19″ rack |
| Optical budget | Variable; jumper quality and handling | Predictable; connectorized paths, sub-1 dB typical per switch |
| Power events | Patch state depends on humans | Passive-latching retains live paths through outages |
| Maintenance | Craft required; disruptive | In-service module swaps with audit control |
| OPEX impact | Truck rolls; long change windows | Fewer truck rolls; faster turn-ups and re-homes |
Field vs. lab: All specifications above reflect connectorized, field-deployable performance—not best-case laboratory conditions with fusion splices.
Automated switching isn't just faster—it's more auditable than manual patching.
Every cross-connect change flows through a defined process: request → approval → execution → verification → logging. No ad-hoc changes, no undocumented modifications, no "I think someone patched that last Tuesday."
The switch exposes standard interfaces for integration with your operational stack:
Change logs capture timestamp, operator ID, source port, destination port, and completion status. When a customer disputes a service issue or an auditor asks for change history, the data exists and is exportable.
Role-based access controls determine who can request changes, who can approve them, and who can execute emergency overrides. Multi-factor authentication is supported for sensitive operations. All management traffic can be encrypted in transit.
Automated switching isn't just faster—it's more auditable than manual patching.
One rack, one cabinet, limited fiber count. The automated switch replaces a manual patch panel, enabling remote provisioning without dedicated on-site staff.
Typical config: 72 ports (simplex) or 144 ports (duplex) in 2U.
Dual uplinks, redundant paths, multiple tenant connections. The switch provides both primary provisioning and protection switching capability—failover paths pre-provisioned and tested.
Typical config: Redundant switches or single switch with diverse port allocation.
Template-based deployment across dozens or hundreds of edge locations. Standardized trunking, consistent port models, identical approval workflows. New sites come online with the same operational model as existing sites.
What you define once and replicate everywhere:
The business case for automated edge switching is straightforward: fewer truck rolls at scale.
A single edge site might generate 2–4 patching events per month. Across fifty sites, that's 100–200 dispatches per year. At fully-loaded technician costs of $150–300 per dispatch, the annual spend on routine patching alone reaches $15,000–60,000—before accounting for delays, errors, and rework.
Typical payback: 12–18 months in active deployments, faster for high-change-velocity environments like carrier hotels or MEC aggregation points.
Price positioning: Cost per port is comparable to premium manual ODF solutions. You're not paying a significant premium for automation—you're reallocating capital from ongoing truck rolls to upfront infrastructure.

Edge infrastructure shouldn't require more manual intervention than core infrastructure. Automated fiber switching brings Layer 0 into the same operational model as everything above it: API-driven, auditable, and remotely controllable.
What's the difference between "zero-touch" and fully automated provisioning?
Zero-touch means no routine physical intervention for standard moves/adds/changes. Provisioning can still require human approval in the workflow—the automation is in execution, not decision-making.
Can automated switches handle protected paths?
Yes. Pre-provision primary and secondary paths, then trigger failover via API or manual command when needed. Some deployments automate failover based on loss-of-light detection.
What happens during a power outage?
Passive latching maintains all established connections through power loss. Paths don't reset or drop. When power returns, the switch resumes management capability with all connections intact.
How does this integrate with our existing OSS/BSS?
REST API and SNMP interfaces allow integration with standard provisioning and monitoring systems. Most deployments start with GUI-based operations and add API integration as automation matures.